# Power Distribution API
The module power supports 3 kinds of devices:
- Generators: Provide power, can be turned on/off
- Consumers: Need power, like machines or lamps, can be turned on/off
- Batteries: Can provide stored power, combination of generator and consumer
### Possible connection sides
```
U(p) B(ack)
| /
| /
+--|-----+
/ o /|
+--------+ |
L(eft) ----| |o---- R(ight)
| o | +
| / |/
+--/-----+
/ |
F(ront) |
|
D(own)
```
All 3 kinds of nodes use the same registration function to enrich the nodes functionality for power distribution.
techage.power.register_nodes(names, definition)
-- names is a list of node names
-- definition is a table according to:
{
on_power_pass1 = func(pos, mem), -- for power balance calculation
on_power_pass2 = func(pos, mem, sum), -- for power balance adjustment
on_power_pass3 = func(pos, mem, sum), -- for power balance result
conn_sides = <list>, -- allowed connection sides for power cables
-- one or several of {"L", "R", "U", "D", "F", "B"}
power_network = <tubelib2-instance>,
}
**Pass1: Power balance calculation** `on_power_pass1`
Return the currently needed amount of power.
For batteries, switch to uncharging and return the uncharging value (negative value).
**Pass2: Power balance adjustment** `on_power_pass2`
Provides the current power balance. A positive sum means, more power available then needed.
A battery can turn off or even switch to charging if the balance is positive.
In this case, return the correction value (a positive value) instead of 0.
In case of a consumer: turn off if power balance is negative and return the correction value (a negative value).
**Pass3: Power balance result** `on_power_pass3`
Function provides the final power balance for output purposes.
techage.power.power_distribution(pos)
-- Trigger the recalculation or the power distribution in case of
-- a turn on/off request
techage.power.formspec_power_bar(max_power, current_power)
-- returns the formspec PGN with a bar according the the ratio `current_power/max_power`
techage.power.formspec_load_bar(charging)
-- returns the formspec PGN with the charging/uncharging symbol
-- charging can be:
-- true => charging
-- false => uncharging
-- nil => turned off
### Internas
The function `techage.power.register_nodes`:
- adds a wrapper to `after_place_node` (needed to maintain tubelib2 data base)
- adds a wrapper to `after_dig_node` (needed to maintain tubelib2 data base)
- adds the function `after_tube_update` (needed to maintain tubelib2 data base)
- adds the table `power` to the node definition with the provided attributes
- adds `power_dirs` to the node meta table with the `conn_sides` information converted to node specific dirs
- adds `mem.connections` for the available power connections with consideration of valid `power_dirs`